Mechanical
| IP Rating | IP20 |
|---|---|
| Fitting Colour | |
| EV-MERCURY-CORE-24M-B EV-MERCURY-CORE-24M-F&P-B EV-MERCURY-ONE-24M-B | Black |
| EV-MERCURY-CORE EV-MERCURY-CORE-24M-F&P EV-MERCURY-ONE-24M | White |
| Body Material | Polycarbonate |
| Diffuser Material | Polycarbonate |
| Installation Type | Wall or Ceiling |
Electrical
| Working Temp Range | 0 to 40 °C |
|---|---|
| Input Frequency | 50 Hz |
| Maximum Wattage | |
| EV-MERCURY-CORE-24M-B | 1.6 W |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | 2.5 W |
| EV-MERCURY-CORE | 3.5 W |
| Input voltage | |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | 220-240VAC |
| EV-MERCURY-CORE EV-MERCURY-CORE-24M-B EV-MERCURY-CORE-24M-F&P EV-MERCURY-CORE-24M-F&P-B | 230Vac |
| Standby Power | |
| EV-MERCURY-CORE-24M-B | 1.2 W |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | 1.9 W |
| EV-MERCURY-CORE | 2.2 W |
| Standby power for non-maintained/switched maintained emergency devices is measured when the light is off and the charger is in standby mode. For maintained emergency devices, standby power is measured when the light is on and the charger is in standby mode. Typically, charging occurs for the first 16 hours after the device is powered or after a battery discharge. | |
Driver
| Driver Type | |
|---|---|
| EV-MERCURY-CORE EV-MERCURY-CORE-24M-B EV-MERCURY-CORE-24M-F&P EV-MERCURY-CORE-24M-F&P-B | Fixed output |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | Lynk Wireless or DALI-2 with DT1 |
| Driver Included | Yes |
| Integrated Driver | Yes |
| Wiring Type | |
| EV-MERCURY-CORE-24M-F&P EV-MERCURY-CORE-24M-F&P-B | Re-wireable Flex & Plug (2 pin) |
| EV-MERCURY-CORE | Re-wireable terminal block (3 pin) |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | Re-wireable terminal block (4 pin) |
| Flex & Plug or Lead Length | 600 mm |
Emergency (EM suffix)
| Emergency Mode | Maintained |
|---|---|
| Emergency Classification | |
| EV-MERCURY-CORE EV-MERCURY-CORE-24M-F&P EV-MERCURY-CORE-24M-F&P-B | C0:D3.2,C90:D3.2 |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | D6.3 |
| Emergency Output Power | 600 mW |
| Replacement Battery Code | |
| EV-MERCURY-CORE EV-MERCURY-CORE-24M-B EV-MERCURY-CORE-24M-F&P EV-MERCURY-CORE-24M-F&P-B | 12425 |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | 13972 |
| Emergency Duration | 90 mins |
| Emergency Lumen Output | 40 lm |
| Viewing Distance | 24 m |
| Decal Size | 300 x 150 mm |
| Emergency Control | |
| EV-MERCURY-CORE EV-MERCURY-CORE-24M-B EV-MERCURY-CORE-24M-F&P EV-MERCURY-CORE-24M-F&P-B | Ektor SafeTest (Automatic self-test) |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | Lynk Wireless or DALI-2 |
| Emergency Light Source Life | 56Y/06M |
| AS2293.3-2018 Projection of Light source life for LED Exit signs (appendix E) Defines the projected time until the surface luminance falls below the minimum required surface luminance for an exit sign. | |
Compliance
| Standards |
|
|---|
Warranty
| Warranty | |
|---|---|
| EV-MERCURY-CORE EV-MERCURY-CORE-24M-B EV-MERCURY-CORE-24M-F&P EV-MERCURY-CORE-24M-F&P-B | 5 Year Warranty, First 2 Years Onsite |
| EV-MERCURY-ONE-24M EV-MERCURY-ONE-24M-B | 8 Year Warranty, RTB |
| The total warranty period is shown above. Where an on-site period is listed, the first years are covered on-site, with return-to-base coverage for the remainder. For full warranty details and claim instructions, please refer to our Warranty page. | |