Mechanical
| IP Rating | IP65 |
|---|---|
| IK Rating | IK08 |
| Fitting Colour | Grey |
| Body Material | Polycarbonate |
| Installation Type | Surface mount |
Electrical
| Working Temp Range | |
|---|---|
| EV-SPUR-IP65-1200-F&P | -20 to 40' °C |
| EV-SPUR-IP65-1200-EM-F&P | 220-240V °C |
| Input Frequency | 50 Hz |
| Maximum Wattage | 24 W |
| Input voltage | 220-240V |
Lamp
| Colour Rendering Index (CRI) | >80 |
|---|---|
| CCT Configuration | Single |
LED Lifetime
| LED Lifetime Ratings (Failure rate & lumen depreciation) | |||||||
|---|---|---|---|---|---|---|---|
| |||||||
| This rating defines the performance of the led within its lifetime. L relates to lumen depreciation, where the proceeding number gives the resultant lumen output at the end of it reported lifetime. L70, would mean 30% lumen depreciation which means 70% of its initial output and is tested accordingly to TM-21. The B part refers to failures, which can be define as the percentage of LEDs which fall below the L value in the projected lifetime. A value of B10 refers to 10% failure and a value of B50 refers to 50% failure. After the defined lifetime, the system will reach the defined lumen depreciation and the average led failures is defined by the B rating. The B rating is defined in and tested to IEC62717. | |||||||
Colour temperature
| CCT Colour | Cool White |
|---|---|
| Luminaire Lumens | 3600 lm |
| All photometric data has a tolerance of ±10%. Luminaire lumens refers to the exit lumens or delivered lumens from the luminaire. | |
| CCT | 4000K |
Driver
| Flex & Plug or Lead Length | 1200 mm |
|---|---|
| Flicker Free | Yes |
| PSTLM | 1 |
| Short Term Light Modulation (PstLM): The requirement is that PstLM should be less than or equal to 1.0. This metric measures the short-term flicker severity and ensures that flicker is not perceptible or is at a level that does not cause discomfort or health issues. | |
| SVM | 0.4 |
| Stroboscopic Visibility Measure (SVM): The requirement for SVM is that it should be less than or equal to 0.4. The SVM metric assesses the visibility of the stroboscopic effect, which can make moving objects appear to be stationary or moving in discrete steps, thus ensuring that this effect is minimized in lighting environments to prevent visual discomfort and safety hazards. | |
Emergency (EM suffix)
| Emergency Mode | Maintained |
|---|---|
| Emergency Classification | C0:D80,C90:D63 |
| Emergency Output Power | 4700 mW |
| Emergency Duration | 120 mins |
| Emergency Lumen Output | 660 lm |
| Emergency Control | Ektor SafeTest (Automatic self-test) |
Compliance
| Standards |
|
|---|
Warranty
| Warranty | 5 Year Warranty, First 2 Years Onsite |
|---|---|
| The total warranty period is shown above. Where an on-site period is listed, the first years are covered on-site, with return-to-base coverage for the remainder. For full warranty details and claim instructions, please refer to our Warranty page. | |
| Warranty Operating Hours | 15000 hrs |
| This product is provided with a warranty up until the stated warranty period or until the stated warranty operating hours has been reached (whichever occurs first). | |